Gasboy Gilbarco Global Pumping Unit Operation Manual Manuel d'utilisateur Page 25

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 42
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 24
MDE-4447A Global Pumping Unit Operation and Service Manual · May 2008 Page 21
General Vacuum and Pressure Information Troubleshooting
5 – Troubleshooting
General Vacuum and Pressure Information
The following components are normally associated with pump pressure:
Control Valve
Meter
Computer or Pulser Drive Linkage
•Hose
Nozzle
The following components are normally associated with pump vacuum:
•Blades
Rotor/Stator
Filter
Bypass Valve and Seat
Float (opened)
Installation piping
Tank Vent Pipe
Angle Check Valve or Foot Valve
Tank burial depth
Vacuum readings can vary with each installation. To calculate pump vacuum, proceed as
follows:
1 An inch of mercury is required to lift gasoline 1-1/2 feet. Divide the total lift by 1-1/2 feet to
obtain vacuum.
2 Allow an inch of mercury for each angle check, foot valve, or vertical check valve.
3 Allow an inch of mercury for each 60 feet of piping.
4 Add the readings obtained in steps 1, 2 and 3 to determine the approximate vacuum reading at
fast flow.
Note: Excessive vacuum indicates a restriction. Low vacuum indicates a leak.
Vue de la page 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 41 42

Commentaires sur ces manuels

Pas de commentaire