4. Figure out the amount of available transaction space.
Write the following values: ROM TOTAL (From Step 2):
RAM TOTAL (From Step 3):
Consult the following chart to see where your ROM value falls.
ROM TOTAL RANGE BYTES
22513 to 26608 4096
26609 to 30704 8192
30705 to 34800 12288
over 34800
*
*
If your ROM TOTAL exceeds this number, your system
has too many options. Eliminate options.
Write the number listed in the BYTES column:
Perform the following calculation:
RAM Total
+ Bytes = Reserved RAM
+ =
Subtract the Reserved RAM from 33465 to get transaction space.
33465
Reserved RAM = Transaction Space
33465
=
5. Figure out the total number of transactions that can be stored.
Get Transaction Space from Step 4. Write the total in the space provided below.
Get Number of Bytes in Transaction Record from Step 1. Write the total in the space provided
below.
Perform this calculation:
Transaction Bytes in Number of Possible
Space / Transaction Record = Transactions Stored
/ =
Subtract 8
8
Approximate number of transactions that can be stored: